20% OFF shipping at auxtoursdunmonde.com on orders over $79 + up to 10% OFF products
auxtoursdunmonde.com
home > HIMA F3225 4-Channel AND Gate Logic Module for Planar4 Safety Systems > HIMA F3225 4-Channel AND Gate Logic Module for Planar4 Safety Systems
download picture
HIMA F3225 4-Channel AND Gate Logic Module for Planar4 Safety SystemsProduct Description: The HIMA F3313 is a 4 channel High Side Signal Filter Module designed for use in the HIMA Planar4 system, a legacy safety platform renowned for its hardwired reliability and high integrity interlocking. Unlike programmable modules in newer systems (like the H41q H51q), the F3313 is a non programmable, hardware based signal conditioner, ideal for high speed, safety critical environments where physical hardwiring is paramount. This
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols
    • Product Description:

      The HIMA F3313 is a 4-channel High-Side Signal Filter Module designed for use in the HIMA Planar4 system, a legacy safety platform renowned for its hardwired reliability and high-integrity interlocking. Unlike programmable modules in newer systems (like the H41q/H51q), the F3313 is a non-programmable, hardware-based signal conditioner, ideal for high-speed, safety-critical environments where physical hardwiring is paramount.

      This module filters and stabilizes input signals from field devices such as pressure switchesemergency stop buttons, or other digital signals, ensuring high-frequency noise rejection. By removing unwanted EMI (electromagnetic interference) or contact bounce, the F3313 ensures that only clean, stable signals reach the logic system for processing. With its high-side switching, this module operates on the positive leg of a 24 VDC circuit, further enhancing signal integrity and safety.


      Key Features:

      • Hardwired Safety Logic:
        No software or microprocessor involved—reliability is achieved through physical wiring on the backplane, ensuring the highest level of safety and speed.

      • Signal Filtering:
        Specifically designed to remove unwanted noise, including contact bounce and EMI, ensuring that only clean and reliable signals are sent to the safety logic system.

      • High-Side Switching:
        The F3313 switches or monitors the positive leg (L+) of a 24 VDC circuit, making it suitable for a wide range of industrial control and safety applications.

      • Safety Class:
        Capable of integration into systems rated up to SIL 4, depending on the overall architecture of the Planar4 system.

      • Plug-and-Play Installation:
        Easily installed as a plug-in card into the HIMA Planar4 subrack, with no need for programming or configuration, reducing downtime and simplifying maintenance.


      Technical Specifications:

      Parameter Specification Details
      Number of Channels 4
      Input Voltage 24 VDC (-15% to +20%)
      Input Current Approx. 8 mA per channel
      Switching Threshold ON: > 15 VDC
      Delay/Filter Time Typically 1 ms to 10 ms (Hardware fixed)
      Output Type Active logic signal (Internal HIMA Bus)
      Operating Temp 0°C to +60°C (32°F to 140°F)
      Form Factor Plug-in card for HIMA Planar4 subrack

       


      Functional Logic:

      The F3313 serves as the "front door" for digital signals in the HIMA Planar4 system, specifically conditioning and filtering signals from field devices (e.g., pressure switches or E-Stop buttons) before they are processed by safety logic modules. After filtering out noise and unwanted spikes, the module transmits the stabilized signal to internal logic modules (like the F32xx series AND/OR gates), which then perform the required safety actions.


      Maintenance and Replacement:

      • No Programming Required:
        The F3313 operates purely as a hardwired component, meaning it does not require any configuration changes when replaced. If the module fails, it can be swapped out with a spare without needing software updates or IP reconfigurations.

      • Physical Wiring Considerations:
        Because the Planar4 system is hardwired, any changes to the safety logic (e.g., module replacements or adjustments) necessitate physical rewiring and a full re-validation of the safety loop.

      • Pin Alignment:
        The connectors in the Planar4 subrack are fine-pinned, so care must be taken during installation to prevent damage to the pins. Forcing the module into the subrack can cause pin damage.

      • LED Status Indicators:
        Each channel typically has a small LED to indicate whether the input signal is "High" (active). If the LED is off, but 24 VDC is still present at the terminal, it suggests a failure in the internal filter or opto-coupler.

HIMA F3225 4-Channel AND Gate Logic Module for Planar4 Safety Systems

Item no : 44904645164
sold recently : Login >>
US$ 180.00
Pay in 4 interest-free payments of $45.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 29 - Jul 4

Enjoy 20% off shipping

US$ 180.00

1-11

US$ 162.00

12-35

US$ 126.00

36-59

US$ 108.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches